Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Database
Language
Document Type
Year range
1.
Cell ; 185(5): 872-880.e3, 2022 03 03.
Article in English | MEDLINE | ID: covidwho-1699915

ABSTRACT

Although infections among vaccinated individuals lead to milder COVID-19 symptoms relative to those in unvaccinated subjects, the specificity and durability of antibody responses elicited by breakthrough cases remain unknown. Here, we demonstrate that breakthrough infections induce serum-binding and -neutralizing antibody responses that are markedly more potent, durable, and resilient to spike mutations observed in variants than those in subjects who received only 2 doses of vaccine. However, we show that breakthrough cases, subjects who were vaccinated after infection, and individuals vaccinated three times have serum-neutralizing activity of comparable magnitude and breadth, indicating that an increased number of exposures to SARS-CoV-2 antigen(s) enhance the quality of antibody responses. Neutralization of SARS-CoV was moderate, however, underscoring the importance of developing vaccines eliciting broad sarbecovirus immunity for pandemic preparedness.

2.
Clin Infect Dis ; 75(1): e1028-e1036, 2022 Aug 24.
Article in English | MEDLINE | ID: covidwho-1621585

ABSTRACT

BACKGROUND: Although severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infectious virus isolation in outpatients with coronavirus disease 2019 (COVID-19) has been associated with viral RNA levels and symptom duration, little is known about the host, disease, and viral determinants of infectious virus detection. METHODS: COVID-19 adult outpatients were enrolled within 7 days of symptom onset. Clinical symptoms were recorded via patient diary. Nasopharyngeal swabs were collected to quantitate SARS-CoV-2 RNA by reverse transcriptase polymerase chain reaction and for infectious virus isolation in Vero E6-cells. SARS-CoV-2 antibodies were measured in serum using a validated ELISA assay. RESULTS: Among 204 participants with mild-to-moderate symptomatic COVID-19, the median nasopharyngeal viral RNA was 6.5 (interquartile range [IQR] 4.7-7.6 log10 copies/mL), and 26% had detectable SARS-CoV-2 antibodies (immunoglobulin (Ig)A, IgM, IgG, and/or total Ig) at baseline. Infectious virus was recovered in 7% of participants with SARS-CoV-2 antibodies compared to 58% of participants without antibodies (prevalence ratio [PR] = 0.12, 95% confidence interval [CI]: .04, .36; P = .00016). Infectious virus isolation was also associated with higher levels of viral RNA (mean RNA difference +2.6 log10, 95% CI: 2.2, 3.0; P < .0001) and fewer days since symptom onset (PR = 0.79, 95% CI: .71, .88 per day; P < .0001). CONCLUSIONS: The presence of SARS-CoV-2 antibodies is strongly associated with clearance of infectious virus. Seropositivity and viral RNA levels are likely more reliable markers of infectious virus clearance than subjective measure of COVID-19 symptom duration. Virus-targeted treatment and prevention strategies should be administered as early as possible and ideally before seroconversion. CLINICAL TRIALS REGISTRATION: NCT04405570.


Subject(s)
COVID-19 , Communicable Diseases , Adult , Antibodies, Viral , COVID-19 Testing , Humans , Immunoglobulin A , Outpatients , RNA, Viral , SARS-CoV-2
3.
J Clin Microbiol ; 59(9): e0098921, 2021 08 18.
Article in English | MEDLINE | ID: covidwho-1501532

ABSTRACT

With the availability of widespread SARS-CoV-2 vaccination, high-throughput quantitative anti-spike protein serological testing will likely become increasingly important. Here, we investigated the performance characteristics of the recently FDA-authorized semiquantitative anti-spike protein AdviseDx SARS-CoV-2 IgG II assay compared to the FDA-authorized anti-nucleocapsid protein Abbott Architect SARS-CoV-2 IgG, Roche Elecsys anti-SARS-CoV-2-S, EuroImmun anti-SARS-CoV-2 enzyme-linked immunosorbent assay (ELISA), and GenScript surrogate virus neutralization assays and examined the humoral response associated with vaccination, natural protection, and vaccine breakthrough infection. The AdviseDx assay had a clinical sensitivity at 14 days after symptom onset or 10 days after PCR detection of 95.6% (65/68; 95% confidence interval [CI], 87.8 to 98.8%), with two discrepant individuals seroconverting shortly thereafter. The AdviseDx assay demonstrated 100% positive percent agreement with the four other assays examined using the same symptom onset or PCR detection cutoffs. Using a recently available WHO international standard for anti-SARS-CoV-2 antibody, we provide assay unit conversion factors to international units for each of the assays examined. We performed a longitudinal survey of healthy vaccinated individuals, finding that median AdviseDx immunoglobulin levels peaked 7 weeks after first vaccine dose at approximately 4,000 IU/ml. Intriguingly, among the five assays examined, there was no significant difference in antigen binding level or neutralizing activity between two seropositive patients protected against SARS-CoV-2 infection in a previously described fishing vessel outbreak and five health care workers who experienced vaccine breakthrough of SARS-CoV-2 infection, all with variants of concern. These findings suggest that protection against SARS-CoV-2 infection cannot currently be predicted exclusively using in vitro antibody assays against wild-type SARS-CoV-2 spike. Further work is required to establish protective correlates for SARS-CoV-2 infection.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , COVID-19 Vaccines , Humans , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL